The IO and PWM channels are controlled by the CM7 core as the CM7 core is responsible for all control related requirements.

The available PWMs can be controlled using pecontroller_pwm.c drivers. The list of available PWMs is as follows

PWM No Operation as individual channel Operation as Inverted Pair Timer Unit
1, 2 Both Simultaneously Yes HRTIM1-A
3, 4 Both Simultaneously Yes HRTIM1-B
5, 6 Both Simultaneously Yes HRTIM1-C
7, 8 Both Simultaneously Yes HRTIM1-D
9, 10 Both Simultaneously Yes HRTIM1-E
11, 12 One at a time Yes TIM1
13, 14 One at a time Yes TIM1
15, 16 One at a time Yes TIM1
Note